Welcome to the AIRFLOW® Prophylaxis Master support page. Here, you’ll find everything you need, from user guides, FAQs instructional videos and troubleshooting tips to get the most out of your device and all its consumables.
DOCUMENTS
INSTRUCTION FOR USE
TREATMENT RECOMMENDATIONS
DECLARATION OF CONFORMITY
INSTALLATION AND CONNECTION
FAQ
Get Started
How to set temperature and sound of the AIRFLOW® Prophylaxis Master & AIRFLOW® ONE?
Your browser does not support iframes, but you can visit
How to install the AIRFLOW® Prophylaxis Master with Station+?
Your browser does not support iframes, but you can visit
Where to find my serial number?
Under the device, you will find the nameplate. The serial number is written next to SN logo.
How to install the AIRFLOW® Prophylaxis Master & AIRFLOW® ONE with Station?
Your browser does not support iframes, but you can visit
How to use the new AIRFLOW® PLUS Powder aluminum bottle?
Your browser does not support iframes, but you can visit
How to insert and remove the PERIOFLOW® Nozzle?
Your browser does not support iframes, but you can visit
How to install the AIRFLOW® Prophylaxis Master?
Your browser does not support iframes, but you can visit
How to insert and remove the PIEZON® PS Instrument?
Your browser does not support iframes, but you can visit
Maintenance
How to reprocess your PIEZON® handpiece?
Your browser does not support iframes, but you can visit
How to reprocess your PERIOFLOW® handpiece?
Your browser does not support iframes, but you can visit
How to pair the wireless pedal with the AIRFLOW® Prophylaxis Master & AIRFLOW® ONE?
Your browser does not support iframes, but you can visit
How to change the O-ring of the PIEZON® cord?
Your browser does not support iframes, but you can visit
How to reprocess and prevent clogging on AIRFLOW® MAX handpiece?
Your browser does not support iframes, but you can visit
How to do everyday maintenance of the AIRFLOW® Prophylaxis Master without Station+?
Your browser does not support iframes, but you can visit
How to do everyday maintenance of the AIRFLOW® Prophylaxis Master with Station+?
To do the water lines cleaning and disinfection, and if you have the AIRFLOW® STATION+, the NIGHT CLEANER bottle must be placed onto the cart. No water bottle on top of the unit. This to ensure 100% cleaning access to all liquid leading lines. Then follow the everyday maintenance cleaning steps on the device
How to clean the powder chamber?
Your browser does not support iframes, but you can visit
Be careful: Only use the air function of the syringe to clean the powder chamber
How to change the O-ring of the AIRFLOW® cord?
Your browser does not support iframes, but you can visit
Troubleshooting — Device
The device is leaking.
/!\ Risk of fire and electric shock.
Stop using your device immediately, disconnect the main plug and contact EMS aftersales service.
Too much powder and not enough water.
Your browser does not support iframes, but you can visit
Insufficient air and powder coming out.
Your browser does not support iframes, but you can visit
Water does not seem to be warm enough on PIEZON® side.
Your browser does not support iframes, but you can visit
Bottle is leaking.
Your browser does not support iframes, but you can visit
The device is whistling or making strange noises.
/!\ Risk of bottle explosion.
/!\ First disconnect the mains plug.
This symptom is generally caused by a problem to the pressure regulator (fault or low temperature) or by a crack in the water bottle.
1. Stop using your device immediately and disconnect it from the grid.
2. Check the bottle in use for crack or any damage and, if the case, replace it with a new one.
3. Check the supplied air pressure: it shall be 4.5 bar minimum. 6 bar ideally.
4. If the device temperature is below 10°C (device too cold), wait for it to warm-up at ambient temperature and then reconnect to the power grid and switch it on again.
5. If the device temperature is over 10°C, or the problem recurs, definitively stop using it and contact EMS aftersales service.
The device is not turning on.
Check the electrical connection and power socket to make sure the device is properly plugged in.
If the device is properly plugged in there might be an issue with the fuses.
If still not solved, contact EMS aftersales service.
The numbers on the device are fading.
Use a cleaning and disinfecting wipe (less than 35% alcohol) that complies with the standards applicable in the country.
EMS recommends the use of either — CleanWipes, IC-100 or PlastiSept Eco Wipes from ALPRO MEDICAL GmbH. — Micro-Kleen3™ Surface Disinfectant Wipes from Micro-Scientific. — CaviWipes1™ or Caviwipes™ 2.0 from Metrex Wipe and dry the device after disinfection and/or decontamination. Once a week use a damp micro fiber cloth with warm water to remove the residue build up that all wipes can leave on your AIRFLOW® Prophylaxis Master & AIRFLOW® ONE, cords and handpieces followed by a dry off with a soft non lint cloth
DO NOT use paper towels as these can be abrasive. Follow carefully the instructions provided by the wipes manufacturer. DO NOT use CaviWipes™ or Advantaclear wipes. They damage EMS products.
The device is making smoke (and fire).
/!\ Risk of fire and electric shock.
/!\ First disconnect the mains plug.
Stop using your device immediately, disconnect it and contact EMS aftersales service.
Temperature or sound of the AIRFLOW® Prophylaxis Master & AIRFLOW® ONE is not what I want.
Go to GET STARTED section and select How to: Set temperature and sound of the AIRFLOW® Prophylaxis Master & AIRFLOW® ONE?
Troubleshooting — Led Lights
LED 4 BLINKING orange
/!\ Risk of fire and electric shock.
/!\ First disconnect the mains plug.
1. Your device is too hot. Disconnect the device for an hour and then turn it on again.
2. Your device is too cold. Wait for the device to warm up to room temperature and try to turn it on again.
If still not solved, contact EMS aftersales service.
Note: This error is also displayed while the device is operated under the minimum temperature (operating conditions: 10 °C to 35°C). In this case, wait for the device to warm up to the ambient temperature.
LED 1 SOLID orange
This is an automatic reminder for maintenance service.
It is time to send your device to your yearly maintenance service. Contact EMS aftersales service.
LED 2 SOLID orange
The foot pedal 2x AA lithium batteries need to be replaced.
Alternatively, you might need to re-pair the foot control with the unit.
Perform a new pairing by watching the video on the maintenance chapter. Go to MAINTENANCE section and select How to pair the wireless pedal with the AIRFLOW® Prophylaxis Master & AIRFLOW® ONE?
LED 3 BLINKING orange
AIRFLOW® and PIEZON® handpiece cords are not detected or missing. At least one cord system is required to operate the device. You will need to re-connect the cords.
1. Switch the device off
2. Underneath the device, slide the lever towards you and pull the black connector out.
3. Disconnect both AIRFLOW® and PIEZON® handpiece cords and clean the electric contacts (jacks) present on the cord system connections. Also blow air to clean the device connection receptacles.
4. Reinstall both handpiece cords: insert the black connector back into the slot making sure the white dot on the connector is aligned with the black dot on the device and push it in hard until you see the green/lock appearing
5. Start the device again.
If still not solved, contact EMS aftersales service.
LED 3 SOLID orange
The problem may have multiple causes. A step-by-step multiple checks are required.
1. The pedal is not detected (at least one pedal must be connected to operate the device):
2. Wired pedal may be disconnected. Check if the jack is fully inserted. Restart the device.
3. Wireless pedal is not paired. Perform a new pairing by watching the video on the maintenance chapter. Go to MAINTENANCE section and select How to pair the wireless pedal with the AIRFLOW® Prophylaxis Master & AIRFLOW® ONE?
If still not solved, contact EMS aftersales service.
LED 1 BLINKING orange
Permanent or transitory hardware fault condition detected.
1. Unplug the device power cord
2. Wait for 30 seconds
3. Plug it back again and restart the device If still not solved, contact EMS aftersales service.
Troubleshooting — Powders Chambers
Powder chamber is not pressurizing.
Your browser does not support iframes, but you can visit
O-rings are missing.
If the cap’s top O -ring is missing, a new cap is needed. If the caps inner O-ring is missing or damaged, a new O-ring is required. If the O-ring located at the bottom cover of the bottle is missing, the entire bottom cover must be replaced. If this doesn’t help, replace the powder chamber or bottle lid with a new piece or contact EMS service support.
White light is blinking at pressurization.
Either the air line is not connected or there is not enough air pressure.
1. Check the air line for no kinking and check the air compressor unit. Air compressor should delivered 4.5 bar pressure, 6 bar ideally.
2. Check air filter for cleanliness and replace if dirty.
If still not solved, contact EMS aftersales service.
Powder is spraying out of the powder chamber at depressurization.
1. Powder chamber is filled beyond the maximum level marked.
2. Remove the powder exceeding the MAX sign on the bottle.
3. Check the small seal on the powder chamber lead for being worn out/ replace if necessary the lid or big seal BC-262 for lid. If still not solved, contact EMS aftersales service
Powder chamber is not depressurizing.
Your browser does not support iframes, but you can visit
White light is blinking at depressurization.
The problem may have multiple causes. A step-by-step multiple checks are required. The AIRFLOW® Handpiece may be clogged.
1. Follow the maintenance process to prevent or unclogg the handpiece by watching the video on the maintenance chapter. Go to MAINTENANCE section and select How to reprocess and prevent clogging on AIRFLOW® MAX handpiece?
If the unclogging of the handpiece doesn’t fix the issue it may indicate a clogged AIRFLOW® cord.
2. Dismount and clean the AIRFLOW® cord extremity.
3. Blow with compressed air through the one end and then repeat fro the other end. If there is no air coming out, the AIRFLOW® cord is clogged.
If still not solved, contact EMS aftersales service.
The powder in the powder chamber is not whirling.
The problem may have multiple causes. A step-by-step multiple checks are required. Remove the AIRFLOW® Handpiece and try to pressurize the powder chamber. If the powder chamber pressurize:
1. The Handpiece may be clogged. Follow the maintenance process to prevent or unclogg the Handpiece by watching the video on the maintenance chapter. Go to MAINTENANCE section and select How to reprocess and prevent clogging on AIRFLOW® MAX handpiece?
If the powder chamber do not pressurize, 2 options:
1. The issue is the same with both powder chamber — The air pressure may not be sufficient. Check if the compressor is on and the device is correctly connected. If necessary, contact your technician and check the air pressure.
2. The issue is not the same with both powder chamber — The powder may be stuck inside the chamber. Shake the powder chamber properly before use. — If this doesn’t help, remove the powder from the powder chamber, dry it using compressed air and add new powder. — If this doesn’t help, perform the whole chamber cleaning process. Follow the maintenance process to clean the powder chamber by watching the video on the maintenance chapter. Go to MAINTENANCE section and select How to clean the powder chamber?
Powder chamber is leaking.
Clean the powder chamber, the cap and the bottom O-rings with a wet cloth. Also, clean the connecting elements on the device.
If the issue is not resolved, you might have to replace the powder chamber or the bottle lit with a new one, please contact EMS aftersales service.
Troubleshooting — Bottle
Bottle connection is leaking.
1. Ensure the bottle cap has been correctly closed.
2. Clean the connection: cap and device sides.
3. If the bottle is still leaking, inspect the bottle and cap for any cracks.
4. Replace the bottle in case the bottle is damaged If still not solved, contact EMS aftersales service.
Still some blue liquid remaining after rinsing
1. Make sure you have set your water regulators to 10: maximum flow on the cords.
2. Make sure you have well-connected cords and sufficient pressure (air pressure: 4.5 to 7 bar. Ideally 6 bar. / water pressure: 2 to 5 bar)
3. Perform a second rinsing phase before treatment. If still not solved, contact EMS aftersales service.
Bottle is leaking.
Your browser does not support iframes, but you can visit
Troubleshooting — AIRFLOW® and PIEZON® Cords
Water leakage at connection with the handpiece.
Check if the handpiece is properly connected
For AIRFLOW® cord: In case of leakage at the AIRFLOW® Handpiece connection with the AIRFLOW® cord, replace the o-rings of the cord with the spare provided in the EL-1076 Kit located in the AIRFLOW® application box. Follow the maintenance process by watching the video on the maintenance chapter. Go to MAINTENANCE section and select How to change the O-ring of the AIRFLOW® cord?
For PIEZON® cord: In case of leakage at the PIEZON® handpiece connection with the PIEZON® cord, replace the o-rings of the cord with the spare BC-083 provided in the PIEZON® application box. Follow the maintenance process by watching the video on the maintenance chapter. Go to MAINTENANCE section and select How to change the O-ring of the PIEZON® cord?
If still not solved, contact EMS aftersales service.
Powder leaks under the AIRFLOW® cord.
The AIRFLOW® pinching element might be worn out or the air interface is dirty and is leaking powder.
1. Disconnect the cord, clean the air jack and connect again.
2. If still not solved, contact EMS aftersales service.
Air leaks from the AIRFLOW® cord.
The AIRFLOW® cord pinch valve is not closing. Contact EMS aftersales service.
Water leakage at the connection with the device.
/!\ Risk of fire and electric shock.
It may be time to replace O-rings.
1. Turn the device off
2. Under the device, move the lever towards yourself and take out the black part (connector) of the cord.
3. Check the integrity of the O-rings.
O-rings are worn out: contact EMS aftersales service to obtain them
O-rings are not worn out: The cable may not be properly connected. Check the cord connections.
If still not solved, contact EMS aftersales service.
The cord is not detected.
1. Turn off the device.
2. Under the device, move the lever towards yourself and take out the black part (connector) of the cord
3. Check the connector for dried Night Cleaner. If there are traces of it, clean them.
4. For PIEZON® only, check the pins on connector with the handpiece. If the pins on the cord are oxidized or have night cleaner inside the pins, clean the pins or replace the cord.
If still not solved, contact EMS aftersales service.
Troubleshooting — Foot Control
Wired pedal does not work.
1. Disconnect and reconnect the pedal.
2. Check the cable for damage.
3. Restart the device.
If still not solved, contact EMS aftersales service.
Foot Control is not activating the device.
Make sure the foot control is correctly positioned in front of the device and nothing/no one is positioned between the device and the foot control.
Make sure you are using lithium batteries.
Alternatively, you might need to re-pair the foot control with the unit.
Perform a new pairing by watching the video on the maintenance chapter. Go to MAINTENANCE section and select How to pair the wireless pedal with the AIRFLOW® Prophylaxis Master & AIRFLOW® ONE?
If still not solved, contact EMS aftersales service.»
Wireless pedal does not work.
In the case is evident that the pedal remained pressed for longer than 10min, simply turn off the device and try again.
If not this case, the problem may have multiple causes. A step-by-step multiple checks are required:
1. Switch-off the device, disconnect and reconnect both the AIRFLOW® and PIEZON® cord. Try again.
2. Perform a new pairing. Watch the video on the maintenance chapter. Try again.
3. Change the 2x AA lithium batteries. Perform a new pairing by watching the video on the maintenance chapter. Go to MAINTENANCE section and select How to pair the wireless pedal with the AIRFLOW® Prophylaxis Master & AIRFLOW® ONE? Try again.
If still not solved, contact EMS aftersales service.
Troubleshooting — Handpieces
Insufficient air and powder coming out.
Your browser does not support iframes, but you can visit
White PIEZON® LED is not working.
1. Clean and dry the handpiece connection and try again.
2. Your PIEZON® Handpiece LED might have been switched off by activity time-outs:
— after 10 minutes of continuous operation,
— or after 20 seconds of inactivity off the holder.
In both cases, put back the handpiece into the holder, wait 1 minute and try again.
If still not solved, contact EMS aftersales service.
Insufficient lighting on the PIEZON® LED.
1. Check the light guide and replace if necessary. The product reference is FV-065.
2. If the light is still weak, replace the handpiece. Contact EMS aftersales service.
Handpiece was dropped.
AIRFLOW® Handpiece:
1. Check the state of the nozzle
2. Replace the handpiece
PERIOFLOW® Handpiece
1 .Replace the nozzle and check the fit of the nozzle.
2. If the PERIOFLOW Nozzle doesn’t hold or it is not watertight, please contact EMS aftersales service.
PIEZON® Handpiece
If the PIEZON® Handpiece falls on the PIEZON® Instrument: Replace the PIEZON® Instrument Check the state of the nozzle. If the PIEZON® Handpiece doesn’t work or in case of doubt, contact EMS aftersales service
How to unclog the AIRFLOW® MAX handpiece ?
Your browser does not support iframes, but you can visit
Insufficient or no water from handpiece.
For all handpieces: Make sure you have set your water to 10 (maximum flow on the cord)
AIRFLOW® Handpiece
1. Verify that the handpiece is not clogged by removing it and checking the water flow without Handpiece. If the Handpiece is clogged, follow the maintenance process to prevent or unclogg the handpiece by watching the video on the maintenance chapter. Go to MAINTENANCE section and select How to reprocess and prevent clogging on AIRFLOW® MAX handpiece?
2. Check your water filter cleanliness and replace it if necessary. Disconnect the mains plug before servicing any filter.
3. Make sure you have well-connected and sufficient pressure from your water supply. If still not solved, contact EMS aftersales service.
PERIOFLOW® Handpiece
1. Change the PERIOFLOW Nozzle
2. Remove the PERIOFLOW Nozzle and verify that a water jet comes out of the handpiece If still not solved, contact EMS aftersales service.
Too much powder and not enough water?
Your browser does not support iframes, but you can visit
Damaged light guide.
Replace the light guide. The product reference is FV-065.
Cracks or stains have appeared.
Make sure you are using approved solution for the reprocessing. Follow the reprocessing instructions on https://eifu.ems-instruction.com/EMS/, select your country and enter the product code FB-358. Ensure that the Handpiece is fully dried before sterilization.
Water does not seem to be warm enough on PIEZON® side.
Your browser does not support iframes, but you can visit
Water leakage at connection with the handpiece.
Check if the handpiece is properly connected
For AIRFLOW® or PERIOFLOW® handpiece: In case of leakage at the AIRFLOW® Handpiece connection with the AIRFLOW® cord, replace the o-rings of the cord with the spare provided in the EL-1076 Kit located in the AIRFLOW® application box. Follow the maintenance process by watching the video on the maintenance chapter. Go to MAINTENANCE section and select How to change the O-ring of the AIRFLOW® cord?
For PIEZON® handpiece: In case of leakage at the PIEZON® handpiece connection with the PIEZON® cord, replace the o-rings of the cord with the spare BC-083 provided in the PIEZON® application box. Follow the maintenance process by watching the video on the maintenance chapter. Go to MAINTENANCE section and select How to change the O-ring of the PIEZON® cord?
If still not solved, contact EMS aftersales service.
Difficulties to connect the AIRFLOW® Handpiece.
1. Check the retaining ring in the tip of the cord. This ring should not be damaged and should be correctly positioned.
2. If the ring is too loose, replace it with a new one. Be careful on how the O-ring is installed, it should have the flat area towards the base of the cord and the round part towards the tip of the nozzle. Follow the maintenance process by watching the video on the maintenance chapter. Go to MAINTENANCE section and select How to change the O-ring of the AIRFLOW® cord?
Low or no mechanical power delivered by PIEZON® or vibration perceived.
Your browser does not support iframes, but you can visit
Water leakage between the handpiece and the PERIOFLOW Nozzle (unusual leak of droplets).
1. Check the position of the PERIOFLOW Nozzle and its position on the handpiece
2. Change the PERIOFLOW Nozzle
3. Check for residues between the PERIOFLOW Nozzle and the handpiece
4. Check that nothing affects the alignment of the PERIOFLOW Nozzle
If still not solved, contact EMS aftersales service.
The PIEZON® Handpiece does not work.
Clean and dry the pins on the bottom of the connected handpiece and the cord. Connect both of them back again and try again. If still not solved, contact EMS aftersales service.
Troubleshooting — PIEZON® Instruments
Low or no movement from PIEZON® Instrument.
Your browser does not support iframes, but you can visit
Troubleshooting — Air/Water Hose
Air hose was connected to water source.
Stop using your device immediately and contact EMS aftersales service.
MAINTENANCE AND REPAIRS
EMS offers maintenance and repair services for your device to ensure that it is always working to 100% of its performance.
LEARN MORE
REGISTER MY DEVICE
To register a device, please create a MyEMS account. By registering, you can not only keep track of your registered devices, but also unlock a host of exclusive features and resources. Gain access to comprehensive guidelines, stay informed about the remaining warranty period, explore interactive content and manuals in our media centre, and discover the latest research and findings in our scientific library. Haven’t registered yet? Create your MyEMS account now!
GO TO MY EMS
MATERIAL SAFETY DATA SHEETS
AIRFLOW PLUS CPC
AIRFLOW CLASSIC — CLASSIC COMFORT
AIRFLOW PLUS
AIRFLOW CLASSIC — CLASSIC COMFORT NEUTRAL
BACTERX PRO
AIRFLOW ERYTHRITOL TOOTHPASTE
BIOFILM DISCLOSER
NIGHT CLEANER
AIRFLOW PERIO
FB—618/AU – rev.E – ed.2019/08
PROPHYLAXIS MASTER
1. BEFORE USE …………………………………………………2
1.1. INTENDED USE ……………………………………………. 3
1.2. APPLICATION FIELDS ……………………………………… 3
1.3. INTENDED USERS …………………………………………. 4
1.4. PATIENT POPULATION …………………………………… 4
1.5. CONTRAINDICATIONS ……………………………………. 5
1.6. COMPATIBILITY …………………………………………… 5
1.7. GENERAL PRECAUTIONS …………………………………. 6
2. INSTALLATION ………………………………………………7
2.1. EQUIPMENT INCLUDED IN THE BOX …………………….. 7
2.2. STEP—BY—STEP INSTALLATION ……………………………. 9
2.3. POWDER CHAMBERS …………………………………… 13
2.4. WATER SUPPLY AND PIEZON
®
BOTTLE ……………… 14
2.5. AIRFLOW
®
AND PERIOFLOW
®
HANDPIECES …….. 15
2.6. PIEZON
®
HANDPIECE AND INSTRUMENTS ………….. 16
3. DEVICE USE ……………………………………………….. 17
3.1. INTERFACES ……………………………………………… 17
3.2. TREATMENT SEQUENCE ………………………………… 21
4. OPTIONAL EQUIPMENT ……………………………….. 22
4.1. PERIOFLOW
®
NOZZLES………………………………. 22
4.2. ENDOCHUCK & PI INSTRUMENT ……………………… 22
5. CLEANING & REPROCESSING…………………………. 23
5.1. WATER LINE CLEANING………………………………… 23
5.2. SAFETY INFORMATION ON NIGHT CLEANER ……… 25
5.3. REPROCESSING OF EMS PARTS ……………………….. 26
6. MAINTENANCE & TROUBLESHOOTING …………… 34
6.1. AIRFLOW
®
HANDPIECE POWDER UNCLOGGING ……. 34
6.2. AIRFLOW
®
HANDPIECE LEAKAGE …………………….. 34
6.3. PIEZON
®
LIGHT GUIDE CHECK & REPLACE …………… 34
6.4. HANDPIECE CORD REPLACEMENT ……………………… 35
6.5. MONTHLY CHECK ……………………………………….. 35
6.6. YEARLY MAINTENANCE & REPAIR ……………………… 36
6.7. PAIRING A NEW PEDAL ………………………………….. 36
6.8. TROUBLESHOOTING …………………………………….. 37
6.9. TO CONTACT EMS SERVICE SUPPORT ………………… 40
6.10. TO REPORT AN ADVERSE EVENT ………………………. 40
7. SUSTAINABILITY ………………………………………… 41
7.1. DISPOSAL OF WASTE PARTS ……………………………. 41
7.2. SUSTAINABLE DESIGN …………………………………… 41
8. WARRANTY ………………………………………………. 41
9. TECHNICAL DESCRIPTION …………………………….. 42
9.1. SYMBOLS …………………………………………………. 43
9.2. ELECTROMAGNETIC COMPATIBILITY ………………….. 45
10. ALPHABETICAL INDEX …………………………………. 47
FOR USE
(FOR AUSTRALIA & NEW
ZEALAND ONLY)
®
EMS AIRFLOW Prophylaxis Master Dental equipment PDF User Guides and Manuals for Free Download: Found (4) Manuals for EMS AIRFLOW Prophylaxis Master Device Model (Manual , User Manual Manual)
The EMS AIRFLOW Prophylaxis Master is an innovative product designed to revolutionize the dental hygiene experience. Focusing on both efficacy and patient comfort, this device integrates cutting-edge technology that stands out in the realm of dental prophylaxis. Users can expect not just a cleaning, but a comprehensive oral care experience.
One of the key features of the EMS AIRFLOW Prophylaxis Master is its advanced air-polishing function. This system utilizes a combination of warm water, air, and specially formulated powder to effectively remove biofilm, stains, and other debris from teeth and gums. The gentle yet thorough polishing leaves the enamel intact while ensuring a brighter smile. The benefits include:
- Enhanced removal of plaque and stains
- Non-invasive cleaning method
- Comfort for patients, even during longer sessions
Another impressive aspect of the EMS AIRFLOW Prophylaxis Master is its adaptability. The device allows for multiple settings, making it suitable for different patient needs and varying degrees of plaque buildup. This means that dental professionals can customize treatments tailored to individual patients, which not only improves results but also enhances the overall patient experience. The user-friendly interface makes it simple to adjust settings, allowing for swift transitions between different cleaning modes.
The ergonomic design of the AIRFLOW Prophylaxis Master means that it can be comfortably handled by dental practitioners. This reduces fatigue during procedures, thus ensuring a high standard of care. With its lightweight body and intuitive grip, the device is designed for both functionality and ease of use. In addition, the low noise levels during operation make the treatment more pleasant for patients who may have anxieties related to dental visits.
The maintenance of the EMS AIRFLOW Prophylaxis Master is also noteworthy. The device features a self-cleaning mechanism that prevents cross-contamination, ensuring that hygiene standards are maintained. Regular maintenance is simplified, allowing dental practices to keep the equipment in optimal condition without extensive effort. This feature not only enhances patient safety but also extends the lifespan of the product.
Patient feedback has been overwhelmingly positive with reports of increased satisfaction, particularly regarding the comfort level of treatment. Many patients have noted that they appreciate the gentler approach of the AIRFLOW system compared to traditional methods. The lack of vibrations and the minimal sensation of discomfort associated with air polishing have transformed dental prophylaxis into a more acceptable experience for many.
Furthermore, the integration of EMS technology into the AIRFLOW Prophylaxis Master has significantly improved the overall cleaning efficiency. Dental practitioners can achieve results that not only enhance aesthetics but also contribute to better oral health. This level of effectiveness has the potential to reduce follow-up visits and further dental procedures, ultimately saving both time and resources for both the patient and the practitioner.
In conclusion, the EMS AIRFLOW Prophylaxis Master represents a leap forward in dental hygiene technology. Its advanced air-polishing capabilities, ergonomic design, and easy maintenance make it a valuable addition to any dental practice. The exceptional results and positive patient experiences further solidify its place as a leader in modern dental prophylaxis solutions. Whether you are a dental professional seeking efficiency or a patient desiring comfort during treatment, the AIRFLOW Prophylaxis Master stands out as an exemplary choice.
AIRFLOW Prophylaxis Master от компании EMS: уникальное решение для лечения кариеса, профилактики заболеваний пародонта и поддерживающей терапии.
Преимущества
- Piezon NO PAIN
Генерирует 32 000 возвратно-поступательных колебаний в секунду без каких-либо боковых прогибов, гарантируя предсказуемые и высокоточные результаты лечения. Имеет встроенную функцию динамической коррекции коэффициента мощности, адаптирующей выходную мощность согласно нагрузке, приложенной к рабочему инструменту, что обеспечивает максимальный комфорт для пациента.
- Высокоточный спрей
Благодаря узкой форме насадки PERIOFLOW, минимально инвазивным путём создается доступ к пародонтальным карманам, композитным реставрациям и имплантатам без необходимости снятия коронок или демонтажа ортодонтических конструкций.
- Эргономичный наконечник
Тонкие и лёгкие наконечники предлагают лучшие манипуляционные возможности и снижают вероятность утомления руки. Благодаря непревзойдённой износостойкости, нормативный срок эксплуатации предусматривает более 1000 циклов стерилизации.
- Контроль температуры
Уникальная функция настройки температуры воды имеет 5 уровней: вода без подогрева, 25°C, 30°C, 35°C и 40°C — идеальное решение для лечения зубов у детей, пациентов с повышенной чувствительностью зубом и при повторных осмотрах.
Сборка
- Наконечник РIEZON
- Наконечник АIRFLOW
- Наконечник РERIOFLOW
- Ёмкость для порошка – ёмкость для порошка AIRFLOW изготовлена из ударопрочного и химически стойкого полимерного материала, характеризуется высокой производительностью, эргономикой и большой вместимостью.
- Башня давления – новая ультрасовременная система быстрого нагнетания и сброса давления со встроенным магнитным соединением.
- Ёмкости – в комплект входят 2 прозрачные ёмкости: PIEZON и NIGHT CLEANER. Ёмкость PIEZON предусмотрена для использования не только дистиллированной воды, но и специальных дезинфицирующих растворов. Ёмкость NIGHT CLEANER предназначена для средства, которым в конце рабочего дня промывается и дезинфицируется система подачи воды.
- Интерактивная сенсорная панель – простая и эргономичная новая сенсорная панель от компании EMS имеет 10 индикаторов, с помощью которых можно регулировать и вручную настраивать мощность в режимах AIRFLOW и PIEZON. Посредством сенсорной панели также производится регулировка температуры воды и уровня громкости звуковых оповещений в активном рабочем режиме и напоминаний о техническом обслуживании.
- Новый вид шланга – Прочный и более эффективный, новый шланг от компании EMS оснащён системой plug-and-play (подключи и работай), которую можно легко отсоединить и заменить. Трубки для порошка выполнены из хирургической нержавеющей стали, что продлевает их срок службы. Многофункциональный и высокопрочный держатель для наконечника со встроенным регулятором подачи воды.
- Педаль – беспроводная педаль из нержавеющей стали с режимом усиления (boost). 360º доступ к активации мощности.
- Внешние фильтры – прозрачные фильтры воздуха и воды позволяют легко контролировать их текущее состояние.
- Система прочистки (РURGE) – полностью интегрированная система автоматической прочистки линии подачи воды в системах Airflow и Piezon. В течение минуты производит очистку от остатков использованного раствора.
- Новая технология NO PAIN – Динамическая коррекция коэффициента мощности, адаптирующая выходную мощность согласно нагрузке, приложенной к рабочему инструменту. Нет отложений зубного камня = низкий уровень мощности. Высокое сопротивление, вызванное наличием зубного камня = повышение мощности в рамках минимальной инвазивности.
- Система подогрева – система с регулировкой температуры воды для обеспечения комфорта во время процедур.
Мобильная станция AIRFLOW STATION
- Станция AIRFLOW STATION+ отличается легкой маневренностью
- Она поворачивается на 360˚ и оснащена 4-колесной тормозной системой
- Полка для хранения предусмотрена для размещения запасных ёмкостей для порошка и флаконов с порошком EMS
- AIRFLOW STATION даёт возможность работать без подключения аппарата к водопроводной сети
- Просто наполните ёмкость водой и подсоедините её к подставке для ёмкости с водой
ПРИМЕНЕНИЕ
Наконечник AIRFLOW
Удаляет биоплёнку, пигментированный налёт и слабоминерализованные зубные отложения. Чистит и полирует во время одной процедуры.
Наконечники AIRFLOW представляют собой новейшую технологию в сфере профессиональной гигиены полости рта и профилактики стоматологических заболеваний. Наконечники нового поколения характеризует высокое качество и долговечность, благодаря использованию материалов медицинского назначения, устойчивых к термо-дезинфекционной обработке. Создаваемая в наконечнике AIRFLOW воздушно-порошковая струя, достигающая скорости более 400 км/ч, обеспечивает эффективное воздействие кинетической энергии, при этом поддерживая однородную форму распыления струи для предсказуемых результатов лечения. В целях обеспечения максимальной эффективности и минимальной дисперсности аэрозольного облака, смешивание воды и порошка происходит непосредственно перед контактом с зубной поверхностью. Пути подачи воздуха и воды в наконечнике AIRFLOW — раздельные, что позволяет производить высокоточную регуляцию потока воды и количества порошка. Благодаря сглаженному дизайну корпуса и лёгкому весу, наконечник AIRFLOW можно удобно держать в руке по типу писчего пера, что в свою очередь облегчает манипуляцию наконечника и обеспечивает доступ к труднодоступным участкам. Стремление компании EMS к инновациям не угасает, кто знает, может новое революционное решение уже совсем близко.
Характеристики
- Угол наклона 120° и узкое сопло наконечника обеспечивают лучший визуальный контроль и доступ
- Полимерный материал медицинского назначения, из которого изготовлен корпус наконечника, обеспечивает высокую прочность и износостойкость
- Термодезинфицируемый и стерилизуемый
- Изящный дизайн для лучших манипуляционных возможностей
- Без риска закупорки
- Небольшой вес и хорошая сбалансированность наконечника снижают риск утомления руки
- Улучшенная эргономика с удобным захватом по типу писчего пера
- Высококачественный поток порошка
- Формирование однородного аэрозольного облака
- Функция немедленного прекращения подачи воды и воздушно-порошковой смеси после снятия ноги с педали управления
- Идеально подходит для длительного использования
- Комфортный для пациентов (без кюрет, без неприятного шума)
- Щадящее применение кинетической энергии
- Без негативного воздействия на поверхности зубов
Наконечник PERIOFLOW
Наконечник PERIOFLOW® представляет собой новейшее технологическое решение для удаление биоплёнки из пародонтальных карманов. Благодаря гибкой насадке и лёгкому весу, он представляет собой идеальное сочетание эргономики и функциональности, а удобное расположение в руке по типу писчего пера снижает усталость и вероятность растяжения кисти руки. Изготовлен из полимерного материала медицинского назначения, который может подвергаться термодезинфекции, наконечник PERIOFLOW обеспечивает высокие стандарты клинической гигиены.
Более того, благодаря трёхсторонней подаче однородной воздушно-порошковой смеси, наконечник PERIOFLOW обеспечивает низкоабразивную обработку внутри парадонтальных карманов. Он идеально подходит для использования при поддерживающей пародонтальной терапии, первичном и вторичном лечении, а также в уходе за дентальными имплантатами и нехирургическом лечении пародонтита и периимплантита.
Характеристики
- Эффективное удаление биоплёнки из глубоких пародонтальных карманов (от 4 до 10 мм)
- Существенное снижение количества бактерий
- Три горизонтально направленные выходные отверстия для воздушно-порошковой смеси и одно апикально направленное отверстие для воды обеспечивают максимальную безопасность и эффективность на 360°
- Легкий вес и удобный захват по типу писчего пера снижают риск утомления руки
- Отметки глубины насадок для контролированного применения (3-5-7-10 мм)
- Автоклавируемый наконечник
- Корпус из пластика медицинского назначения для обеспечения высокой износостойкости
- Функция немедленного прекращения подачи воды, и воздушно-порошковой смеси после снятия ноги с педали управления
- Без риска закупорки
- Повышенная эргономика наряду с изящным дизайном для лучшего визуального контроля и доступа
PERIOFLOW и порошок PLUS предназначены:
- Для удаления поддесневой биоплёнки из пародональных и периимплантных карманов от 4 до 9 мм
- Начальной и поддерживающей пародонтальной терапии
- Профилактики развития мукозита/периимлантита
- Начального и поддерживающего лечения мукозита/периимлантита
Наконечник PIEZON
Ассортимент наконечников PIEZON предлагает непревзойденное качество ультразвука, новые манипуляционные возможности, скорость колебаний, что переопределяет стандарты отрасли, и другие преимущества минимально-инвазивного лечения. Главным элементом здесь является передовая пьезокерамическая ультразвуковая технология, которая в комбинации с инновационным модулем PIEZON NO-PAIN ведут к тому, что все наконечники PIEZON генерируют высокоточные возвратно-поступательные колебания.
Эргономичный дизайн и удобный захват по типу писчего пера являются ведущими факторами усовершенствованных характеристик наконечников PIEZON. Лёгкий вес и небольшой диаметр носика повышают манёвренность и обеспечивают лучший доступ к обрабатываемым участкам. Разработанные с учётом принципов малоинвазивных и максимально комфортных для пациентов методов лечения, наконечники PIEZON оснащены встроенными светодиодами 5000 К, которые излучают яркий дневной свет, а Швейцарские рабочие инструменты PIEZON изготовляются из первоклассной хирургической стали и проходят такой же процесс полировки, как для ювелирных изделий.
После обработки AIRFLOW, следует снять остаточный наддесневой и поддесневой зубной камень с помощью насадки PIEZON NO PAIN PS
Характеристики
- Монолитная конструкция обеспечивающая низкий уровень рабочего шума и вибраций для повышенного комфорта эксплуатации и удобного обслуживания
- Шесть износостойких, герметизированных светодиодов
- 5,000 K обеспечивают более яркое освещение для лучшего обзора
- Aвтоматическое включение и выключение светодиодной подсветки при снятии и исходном размещении наконечника
- Оптимальный диаметр и эргономичный дизайн позволяющие удерживать наконечник по типу писчего пера
- Удобный захват обеспечивает точность, контроль и исключает необходимость приложения чрезмерных усилий
- Легкий вес и удобный захват для снижения риска утомления руки
- Тонкий носик наконечника для обеспечения лучшего визуального контроля и доступа
- Корпус из пластика медицинского назначения гарантирует высокую износостойкость
- Инновационные световоды с микролинзами обеспечивают лучшую обзорность за счёт равномерности распределения света
- Можно подвергать термодезинфекции и стерилизации
Технические характеристики AIRFLOW Prophylaxis Master
- Производитель: EMS SA, Швейцария
- Напряжение: 100-240 В, 50/60 Гц
- Водоснабжение: от 2 до 5 бар (от 200 до 500 кПа)
- Подача сжатого воздуха: от 4,5 до 7 бар (от 450 до 700 кПа)
- Ширина: 260 мм
- Длина: 290 мм
- Высота: 245 мм
- Вес: 5 кг
Комплектация
- AIRFLOW PROPHYLAXIS MASTER — 1 шт
- Наконечник AIRFLOW — 1 шт
- Ёмкость для порошка AIRFLOW PLUS — 1 шт
- Аспирационная насадка ClasenUNO с зеркалом — 1 шт
- Ёмкость для порошка AIRFLOW CLASSIC — 1 шт
- Порошок AIRFLOW PLUS — 12 шт
- Порошок AIRFLOW CLASSIC Comfort — 2 шт
- Наконечник PERIOFLOW — 1 шт
- Насадки PERIOFLOW — 10 шт
- Экстрактор насадок — 1 шт
- Наконечник PIEZON со светодиодной подсветкой — 1 шт
- PIEZON Насадка PS — 1 шт
- PIEZON Насадка Р — 1 шт
- PIEZON Насадка А — 1 шт
- Стартовый комплект PIEZON PI — 1 шт
- Световоды PIEZON — 4 шт
- Ёмкость для PIEZON, 800 мл — 1 шт
- Ёмкость для NIGHT CLEANER — 1 шт
- NIGHT CLEANER Флакон — 1 шт
- CLIP+CLEAN — 2 шт
- Easyclean — 1 шт
- Водный фильтр — 2 шт
- Воздушный фильтр — 2 шт
- Сервисный комплект — 1 шт
- Беспроводная педаль с режимом усиления (BOOST) — 1 шт/
AIRFLOW Prophylaxis Master — это новейший инновационный аппарат для «Guided Biofilm Therapy” от компании EMS: уникальное решение для лечения кариеса, профилактики заболеваний пародонта и поддерживающей терапии.
Предусмотрен для интенсивного профессионального использования, данный аппарат характеризуется уникальной эргономикой, высокой точностью, лёгким обслуживанием и соответствует высоким гигиеническим нормам.
AIRFLOW Prophylaxis Master создан с учётом наивысших стандартов в области производительности, безопасности и комфорта.
Порошок AIRFLOW Plus приятно и эффективно устраняет биоплёнку, пигментацию и слабоминерализованные наддесневые и поддесневые зубные отложения, снижая необходимость использования ручных и ультразвуковых инструментов. Больше никаких резиновых чашечек, щёток и паст. Если требуется, дополнительно производится минимально инвазивный скейлинг с помощью аппарата PIEZON NO PAIN и насадки PS. На комфорт проведения процедуры складываются возможность регуляции температуры воды и управление посредством беспроводной педали.
Преимущества
- Piezon NO PAIN
Генерирует 32 000 возвратно-поступательных колебаний в секунду без каких-либо боковых прогибов, гарантируя предсказуемые и высокоточные результаты лечения. Имеет встроенную функцию динамической коррекции коэффициента мощности, адаптирующей выходную мощность согласно нагрузке, приложенной к рабочему инструменту, что обеспечивает максимальный комфорт для пациента.
- Высокоточный спрей
Благодаря узкой форме насадки PERIOFLOW, минимально инвазивным путём создается доступ к пародонтальным карманам, композитным реставрациям и имплантатам без необходимости снятия коронок или демонтажа ортодонтических конструкций.
- Эргономичный наконечник
Тонкие и лёгкие наконечники предлагают лучшие манипуляционные возможности и снижают вероятность утомления руки. Благодаря непревзойдённой износостойкости, нормативный срок эксплуатации предусматривает более 1000 циклов стерилизации.
- Контроль температуры
Уникальная функция настройки температуры воды имеет 5 уровней: вода без подогрева, 25°C, 30°C, 35°C и 40°C — идеальное решение для лечения зубов у детей, пациентов с повышенной чувствительностью зубом и при повторных осмотрах.
Сборка
- Наконечник РIEZON
- Наконечник АIRFLOW
- Наконечник РERIOFLOW
- Ёмкость для порошка – ёмкость для порошка AIRFLOW изготовлена из ударопрочного и химически стойкого полимерного материала, характеризуется высокой производительностью, эргономикой и большой вместимостью.
- Башня давления – новая ультрасовременная система быстрого нагнетания и сброса давления со встроенным магнитным соединением.
- Ёмкости – в комплект входят 2 прозрачные ёмкости: PIEZON и NIGHT CLEANER. Ёмкость PIEZON предусмотрена для использования не только дистиллированной воды, но и специальных дезинфицирующих растворов. Ёмкость NIGHT CLEANER предназначена для средства, которым в конце рабочего дня промывается и дезинфицируется система подачи воды.
- Интерактивная сенсорная панель – простая и эргономичная новая сенсорная панель от компании EMS имеет 10 индикаторов, с помощью которых можно регулировать и вручную настраивать мощность в режимах AIRFLOW и PIEZON. Посредством сенсорной панели также производится регулировка температуры воды и уровня громкости звуковых оповещений в активном рабочем режиме и напоминаний о техническом обслуживании.
- Новый вид шланга – Прочный и более эффективный, новый шланг от компании EMS оснащён системой plug-and-play (подключи и работай), которую можно легко отсоединить и заменить. Трубки для порошка выполнены из хирургической нержавеющей стали, что продлевает их срок службы. Многофункциональный и высокопрочный держатель для наконечника со встроенным регулятором подачи воды.
- Педаль – беспроводная педаль из нержавеющей стали с режимом усиления (boost). 360º доступ к активации мощности.
- Внешние фильтры – прозрачные фильтры воздуха и воды позволяют легко контролировать их текущее состояние.
- Система прочистки (РURGE) – полностью интегрированная система автоматической прочистки линии подачи воды в системах Airflow и Piezon. В течение минуты производит очистку от остатков использованного раствора.
- Новая технология NO PAIN – Динамическая коррекция коэффициента мощности, адаптирующая выходную мощность согласно нагрузке, приложенной к рабочему инструменту. Нет отложений зубного камня = низкий уровень мощности. Высокое сопротивление, вызванное наличием зубного камня = повышение мощности в рамках минимальной инвазивности.
- Система подогрева – система с регулировкой температуры воды для обеспечения комфорта во время процедур.
Мобильная станция AIRFLOW STATION
- Станция AIRFLOW STATION+ отличается легкой маневренностью
- Она поворачивается на 360˚ и оснащена 4-колесной тормозной системой
- Полка для хранения предусмотрена для размещения запасных ёмкостей для порошка и флаконов с порошком EMS
- AIRFLOW STATION даёт возможность работать без подключения аппарата к водопроводной сети
- Просто наполните ёмкость водой и подсоедините её к подставке для ёмкости с водой
ПРИМЕНЕНИЕ
Наконечник AIRFLOW
Удаляет биоплёнку, пигментированный налёт и слабоминерализованные зубные отложения. Чистит и полирует во время одной процедуры.
Наконечники AIRFLOW представляют собой новейшую технологию в сфере профессиональной гигиены полости рта и профилактики стоматологических заболеваний. Наконечники нового поколения характеризует высокое качество и долговечность, благодаря использованию материалов медицинского назначения, устойчивых к термо-дезинфекционной обработке. Создаваемая в наконечнике AIRFLOW воздушно-порошковая струя, достигающая скорости более 400 км/ч, обеспечивает эффективное воздействие кинетической энергии, при этом поддерживая однородную форму распыления струи для предсказуемых результатов лечения. В целях обеспечения максимальной эффективности и минимальной дисперсности аэрозольного облака, смешивание воды и порошка происходит непосредственно перед контактом с зубной поверхностью. Пути подачи воздуха и воды в наконечнике AIRFLOW — раздельные, что позволяет производить высокоточную регуляцию потока воды и количества порошка. Благодаря сглаженному дизайну корпуса и лёгкому весу, наконечник AIRFLOW можно удобно держать в руке по типу писчего пера, что в свою очередь облегчает манипуляцию наконечника и обеспечивает доступ к труднодоступным участкам. Стремление компании EMS к инновациям не угасает, кто знает, может новое революционное решение уже совсем близко.
Характеристики
- Угол наклона 120° и узкое сопло наконечника обеспечивают лучший визуальный контроль и доступ
- Полимерный материал медицинского назначения, из которого изготовлен корпус наконечника, обеспечивает высокую прочность и износостойкость
- Термо дезинфицируемый и стерилизуемый
- Изящный дизайн для лучших манипуляционных возможностей
- Без риска закупорки
- Небольшой вес и хорошая сбалансированность наконечника снижают риск утомления руки
- Улучшенная эргономика с удобным захватом по типу писчего пера
- Высококачественный поток порошка
- Формирование однородного аэрозольного облака
- Функция немедленного прекращения подачи воды и воздушно-порошковой смеси после снятия ноги с педали управления
- Идеально подходит для длительного использования
- Комфортный для пациентов (без кюрет, без неприятного шума)
- Щадящее применение кинетической энергии
- Без негативного воздействия на поверхности зубов
Наконечник PERIOFLOW
Наконечник PERIOFLOW® представляет собой новейшее технологическое решение для удаление биоплёнки из пародонтальных карманов. Благодаря гибкой насадке и лёгкому весу, он представляет собой идеальное сочетание эргономики и функциональности, а удобное расположение в руке по типу писчего пера снижает усталость и вероятность растяжения кисти руки. Изготовлен из полимерного материала медицинского назначения, который может подвергаться термодезинфекции, наконечник PERIOFLOW обеспечивает высокие стандарты клинической гигиены.
Более того, благодаря трёхсторонней подаче однородной воздушно-порошковой смеси, наконечник PERIOFLOW обеспечивает низкоабразивную обработку внутри парадонтальных карманов. Он идеально подходит для использования при поддерживающей пародонтальной терапии, первичном и вторичном лечении, а также в уходе за дентальными имплантатами и нехирургическом лечении пародонтита и периимплантита.
Характеристики
- Эффективное удаление биоплёнки из глубоких пародонтальных карманов (от 4 до 10 мм)
- Существенное снижение количества бактерий
- Три горизонтально направленные выходные отверстия для воздушно-порошковой смеси и одно апикально направленное отверстие для воды обеспечивают максимальную безопасность и эффективность на 360°
- Легкий вес и удобный захват по типу писчего пера снижают риск утомления руки
- Отметки глубины насадок для контролированного применения (3-5-7-10 мм)
- Автоклавируемый наконечник
- Корпус из пластика медицинского назначения для обеспечения высокой износостойкости
- Функция немедленного прекращения подачи воды, и воздушно-порошковой смеси после снятия ноги с педали управления
- Без риска закупорки
- Повышенная эргономика наряду с изящным дизайном для лучшего визуального контроля и доступа
PERIOFLOW и порошок PLUS предназначены:
- Для удаления поддесневой биоплёнки из пародональных и периимплантных карманов от 4 до 9 мм
- Начальной и поддерживающей пародонтальной терапии
- Профилактики развития мукозита/периимлантита
- Начального и поддерживающего лечения мукозита/периимлантита
Наконечник PIEZON
Ассортимент наконечников PIEZON предлагает непревзойденное качество ультразвука, новые манипуляционные возможности, скорость колебаний, что переопределяет стандарты отрасли, и другие преимущества минимально-инвазивного лечения. Главным элементом здесь является передовая пьезокерамическая ультразвуковая технология, которая в комбинации с инновационным модулем PIEZON NO-PAIN ведут к тому, что все наконечники PIEZON генерируют высокоточные возвратно-поступательные колебания.
Эргономичный дизайн и удобный захват по типу писчего пера являются ведущими факторами усовершенствованных характеристик наконечников PIEZON. Лёгкий вес и небольшой диаметр носика повышают манёвренность и обеспечивают лучший доступ к обрабатываемым участкам. Разработанные с учётом принципов малоинвазивных и максимально комфортных для пациентов методов лечения, наконечники PIEZON оснащены встроенными светодиодами 5000 К, которые излучают яркий дневной свет, а Швейцарские рабочие инструменты PIEZON изготовляются из первоклассной хирургической стали и проходят такой же процесс полировки, как для ювелирных изделий.
После обработки AIRFLOW, следует снять остаточный наддесневой и поддесневой зубной камень с помощью насадки PIEZON NO PAIN PS
Характеристики
- Монолитная конструкция обеспечивающая низкий уровень рабочего шума и вибраций для повышенного комфорта эксплуатации и удобного обслуживания
- Шесть износостойких, герметизированных светодиодов
- 5,000 K обеспечивают более яркое освещение для лучшего обзора
- Aвтоматическое включение и выключение светодиодной подсветки при снятии и исходном размещении наконечника
- Оптимальный диаметр и эргономичный дизайн позволяющие удерживать наконечник по типу писчего пера
- Удобный захват обеспечивает точность, контроль и исключает необходимость приложения чрезмерных усилий
- Легкий вес и удобный захват для снижения риска утомления руки
- Тонкий носик наконечника для обеспечения лучшего визуального контроля и доступа
- Корпус из пластика медицинского назначения гарантирует высокую износостойкость
- Инновационные световоды с микролинзами обеспечивают лучшую обзорность за счёт равномерности распределения света
- Можно подвергать термодезинфекции и стерилизации