Table of Contents
- HD Color screen display
- Functional features
- Output multiple protections
- Professional equipment calibration
- Multi interface display
- Display and operation of main interface
- Statistical interface display and operation
- Voltage current curve interface
- System setting interface
- Data group setting interface
- Product information
- Product mix
- Product Size
- Opening Size
- Product packaging
- Paper shell independent packaging
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
WALFRONT WZ3605E Digital Control Power Supply User Guide
- There is no communication version of this product
- This product is adjustable power supply of DC voltage rise and fall. Please read the instructions before use. Do not con- nect AC or exceed the allowable input voltage range.
HD Color screen display
It adopts 1.44 inch high-definition color screen display and multi screen
display. The output voltage is adjustable from 0.6 V to 36.00V, and the output
current is adjustable from 0 to 5.000A. Small size, high precision, widely
used.
Functional features
- Input reverse connection protection
- 10 data storage
- CV/CC
- Over voltage protection
- Over power protection
- Over current protection
Output multiple protections
Professional equipment calibration
Using high precision sampling chip, low tempeature drift ref- erence power
supply and advanced over sampling and filterin- gAlgorithm, optimize
calibration process, hang up aging test,et- c., to ensure the accuracy and
stability of the productSet!
Multi interface display
Display and operation of main interface
Output on/off setting
In the off state, short press ),turn on output, shour press in open state,
close output.
Set output voltage/current
In the main interface, short press VI, enter the voltage setting state
(reverse red display), press encoder, move and cycle the selected number one
by one, rotate the rotary encoder to change the number to be large small.after
adjustment, press VIA save the current data and exit.30 seconds no operation
will be automat- icsign out. The passage of the same principle (A set the
current quickly.
M1/M2 Data group quick call out
In the main interface, long press (VIA, data group 1 can be called out, and
the lower part of the screen is displayed the column displays the data group
number that has been called up. under data group 1, long press VA to return
data group MO.Same as long press AM3-M9 data group in the required number call
up and set according to group setting interface. Please refer to the
corresponding interface setting instructions.
System zero out
In the main interface, there is a small current. Long press the rotary encoder
to calibrate the output small current drift.
Interface switching
No settings are selected, and the rotary encoder switches menus.
Statistical interface display and operation
Statistics run/pause
In the statistics interface, in the running state, short press the rotary
encoder to pause the statistics. In pause, press the rotary encoder for a
short time under the state, and the opera- tion will be counted.
Clear statistics
In the statistics interface, press and hold the rotary encoder to clear the
statistical information.
Voltage current curve interface
Each grid represents: 0.1V/0.01A Sampling time: 1S
System setting interface
Enter system settings
Long press rotary encoder or short press (A) to enter system setting. The
selected item will be displayed in reverse, short press VIA or A/V switch the
selected entry, and then rotate the encoder to adjust the set-
ting. Set up after setting, press and hold the rotary encoder to save the exit
system settings.
Data group setting interface
M-PRE: 1.Select data group MO-M9; 2. Set call out output.
U-SET: Set the output voltage value.
I-SET: Set the output current value.
S-OVP: Set the overvoltage protection value.
S-OCP: Set the overcurrent protection value.
S-OPP: Set the over power protection value.
S-OHP: Set the maximum run time (parameter is 0,closed by default)
S-OAP: Set the maximum capacity (parameter is 0,closed by default)
S-OWH: Set the maximum energy(parameter is 0,off by de- fault)
Data group setting method
Long press rotary encoder or short press (A to enter data group setting. The
selected item will be reversed, short press VIA or A to switch the selected
items, and then rotate the encoder to adjust the settingsSet.After setting,
press and hold the rotary encoder to save and exit the set- ting.
Product information
| Model:WZ3605E | Display:1.44 inch Color screen |
|---|---|
| Input voltage range:6 00-36.00V | Input voltage resolution:0.1V |
| Output voltage range:0.60-36.00V | Output voltage resolution:0.01V |
| Output current range:0-5.000A | Output current resolution:0.001A |
| Output power range:0-80.000W | Intput voltage accuracy:±(1%+5) |
| Output voltage accuracy:±(0.3%+3) | Output current accuracy:±(0.5%+5) |
| Output ripple:150mV | Temperature 101C-60t |
| Time range:0-10000 hour(unit:S) | Energy range:0-99999.999WH |
| Capacity range:0-99999.999AH | Capacity energy error:±2% |
| Screen brightness:0-6 7 levels | Product Size:794348mm |
Including package weight: about 135g
Product mix
Product Size
Opening Size
For embedded installation, panel opening size is 75mm*39mm
Card slot size
Net weight: about 95g Height of the slot 3.34mm
Product packaging
Paper shell independent packaging
Weight: about 135g (including package)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>
Download This Manual (PDF format)
Download this manual >>
Точные детали:
Функция:
Модель: WZ3605E
Диапазон входного напряжения: 6.00-36.00В
Диапазон выходного напряжения: 0,60-36,00В
Текущий диапазон: 0-5.000A
Диапазон выходной мощности: 0-80.000Вт
Точность выходного напряжения: ±(0.3%+3)
Выходное рябь: 150мВ
Диапазон времени: 0-10000 час (единица:С)
Диапазон емкости: 0-99999.999Ач
Яркость экрана: 0-6 7 уровней
Включая вес упаковки: около 135 г
Дисплей: цветной экран 1,44 дюйма
Разрешение напряжения ввода: 0.1В
Разрешение выходного напряжения: 0.01V
Текущее разрешение: 0.001A
Точность входного напряжения: ±(1%+5)
Текущая точность вывода: ±(0.5%+5)
Температура: -10°C~60°C
Диапазон энергии: 0-99999.999 Вт-ч
Ошибка емкости энергии: ±2%
Размер продукта: 79*43*48 мм
Пакет включает в себя:
1 x WZ3605E
WALFRONT WZ3605E Digital Control Power Supply User Guide
- There is no communication version of this product
- This product is adjustable power supply of DC voltage rise and fall. Please read the instructions before use. Do not con- nect AC or exceed the allowable input voltage range.
HD Color screen display
It adopts 1.44 inch high-definition color screen display and multi screen display. The output voltage is adjustable from 0.6 V to 36.00V, and the output current is adjustable from 0 to 5.000A. Small size, high precision, widely used.
Functional features
- Input reverse connection protection
- 10 data storage
- CV/CC
- Over voltage protection
- Over power protection
- Over current protection
Output multiple protections
Professional equipment calibration
Using high precision sampling chip, low tempeature drift ref- erence power supply and advanced over sampling and filterin- gAlgorithm, optimize calibration process, hang up aging test,et- c., to ensure the accuracy and stability of the productSet!
Multi interface display
Display and operation of main interface
Output on/off setting
In the off state, short press ),turn on output, shour press in open state, close output.
Set output voltage/current
In the main interface, short press VI, enter the voltage setting state (reverse red display), press encoder, move and cycle the selected number one by one, rotate the rotary encoder to change the number to be large small.after adjustment, press VIA save the current data and exit.30 seconds no operation will be automat- icsign out. The passage of the same principle (A set the current quickly.
M1/M2 Data group quick call out
In the main interface, long press (VIA, data group 1 can be called out, and the lower part of the screen is displayed the column displays the data group number that has been called up. under data group 1, long press VA to return data group MO.Same as long press AM3-M9 data group in the required number call up and set according to group setting interface. Please refer to the corresponding interface setting instructions.
System zero out
In the main interface, there is a small current. Long press the rotary encoder to calibrate the output small current drift.
Interface switching
No settings are selected, and the rotary encoder switches menus.
Statistical interface display and operation
Statistics run/pause
In the statistics interface, in the running state, short press the rotary encoder to pause the statistics. In pause, press the rotary encoder for a short time under the state, and the opera- tion will be counted.
Clear statistics
In the statistics interface, press and hold the rotary encoder to clear the statistical information.
Voltage current curve interface
Each grid represents: 0.1V/0.01A Sampling time: 1S
System setting interface
Enter system settings
Long press rotary encoder or short press (A) to enter system setting. The selected item will be displayed in reverse, short press VIA or A/V switch the selected entry, and then rotate the encoder to adjust the set-
ting. Set up after setting, press and hold the rotary encoder to save the exit system settings.
Data group setting interface
M-PRE: 1.Select data group MO-M9; 2. Set call out output.
U-SET: Set the output voltage value.
I-SET: Set the output current value.
S-OVP: Set the overvoltage protection value.
S-OCP: Set the overcurrent protection value.
S-OPP: Set the over power protection value.
S-OHP: Set the maximum run time (parameter is 0,closed by default)
S-OAP: Set the maximum capacity (parameter is 0,closed by default)
S-OWH: Set the maximum energy(parameter is 0,off by de- fault)
Data group setting method
Long press rotary encoder or short press (A to enter data group setting. The selected item will be reversed, short press VIA or A to switch the selected items, and then rotate the encoder to adjust the settingsSet.After setting, press and hold the rotary encoder to save and exit the set- ting.
Product information
| Model:WZ3605E | Display:1.44 inch Color screen |
| Input voltage range:6 00-36.00V | Input voltage resolution:0.1V |
| Output voltage range:0.60-36.00V | Output voltage resolution:0.01V |
| Output current range:0-5.000A | Output current resolution:0.001A |
| Output power range:0-80.000W | Intput voltage accuracy:±(1%+5) |
| Output voltage accuracy:±(0.3%+3) | Output current accuracy:±(0.5%+5) |
| Output ripple:150mV | Temperature 101C-60t |
| Time range:0-10000 hour(unit:S) | Energy range:0-99999.999WH |
| Capacity range:0-99999.999AH | Capacity energy error:±2% |
| Screen brightness:0-6 7 levels | Product Size:79*43*48mm |
| Including package weight: about 135g |
Product mix
Product Size
Opening Size
For embedded installation, panel opening size is 75mm*39mm
Card slot size
Net weight: about 95g Height of the slot 3.34mm
Product packaging
Paper shell independent packaging
Weight: about 135g (including package)
Documents / Resources
tags: Digital Control Power Supply, Power Supply, WALFRONT, WZ3605E, WZ3605E Digital Control Power Supply,
По сути, это миниатюрный лабораторный источник питания, позволяющий выставить выходное напряжение в диапазоне от 0.6 до 36В и ток до 5А. Напряжение можно менять с шагом 0.01, а ток с шагом 0.001А.
WZ3605E оборудован цветным экраном с диагональю 1.44″ на котором отображается самая разная информация о питании, в том числе и график изменения напряжения и тока. Встроенная панель управления позволяет легко регулировать основные параметры и выполнить конфигурирование устройства.
В памяти устройства можно сохранить до 10 рабочих конфигураций, указав не только значения напряжения и тока, но и ограничения по превышению напряжения, тока и мощности, времени работы, отданной мощности и емкости. Для быстрого доступа режимы 1 и 2 выведены на панель управления.
Размеры устройства составляют 79*43*48 мм, а его корпус предусматривает простое встраивание в корпус другого устройства.
Характеристики:
- Входное напряжение: 6-36В;
- Выходное напряжение: 0.6-36В;
- Выходной ток: 0-5А;
- Выходная мощность: 0-80Вт;
- Точность выходного напряжения:±(0,3%+3);
- Точность выходного тока:±(0,5%+5);
- Выходная пульсация: 150 мВ;
- Температура: -10°C~60°C;
- Диапазон времени: 0-10000 часов;
- Диапазон энергопотребления: 0-99999.999 Вт·ч;
- Диапазон емкости: 0-99999.999 Ач.
Ошибка загрузки
{{ $ctrl.loadState$.error.message }}
Не было оценок по данному товару
Средняя оценка: {{ $ctrl.rating_avg | number:1 }}
Наш магазин работает в соответствии с Законом РФ «О защите прав потребителей».
В соответствие с п. 4 ст. 26.1 ФЗ «О защите прав потребителей» и п. 21 Постановления Правительства РФ «Об утверждении правил продажи товаров дистанционным способом» потребитель (покупатель) имеет право отказаться от товара (в том числе и надлежащего качества) в любое время до его передачи, а после передачи – в течение 7 дней. При этом, обмен товара надлежащего качества возможен только в случае, если:
- товар не включен в перечень товаров надлежащего качества, не подлежащих возврату утвержденный Постановлением Правительства РФ №55 от 19.01.1998 г.
- товар не был в употреблении
- сохранены фабричные ярлыки, гарантийные талоны, техническая документация, комплектующие детали
- сохранена упаковка товара
- в наличии документы, подтверждающие факт и условия покупки указанного товара (Ст. 25 Закона «О защите прав потребителей»).
В случае отказа от товара возврату подлежит уплаченная сумма, за исключением расходов на доставку товара, а также других расходов интернет-магазина, подлежащих компенсации за счет Покупателя (Ст. 26.1 Закона «О защите прав потребителей»).
Возвратом и обменом товара занимается тот филиал, в котором была совершена покупка
Дополнительная информация по возврату
Ваш адрес email не будет опубликован. Обязательные поля помечены *
Имя *
Email *
Сайт
Сохранить моё имя, email и адрес сайта в этом браузере для последующих моих комментариев.
Срок проверки reCAPTCHA истек. Перезагрузите страницу.
Вложение
Максимальный размер загружаемого файла: 100 МБ.
Вы можете загрузить: изображение, документ, таблица, текст, архив.
Ссылки на YouTube, Facebook, Twitter и другие сервисы, вставленные в текст комментария, будут автоматически встроены.
Перетащите файл сюда